Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 15(4): 2517-2523, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38633073

RESUMO

Both cataracts and age-related macular degeneration (AMD) may occur with aging and are often developed simultaneously. We performed a study to better characterize the impact of induced scatter on the quality of vision in the near periphery, a region where individuals with AMD typically maintain their functional vision. We used an optical instrument as a cataract simulator based on projecting at the eye's pupil plane phase masks with controlled spatial properties generated with a spatial light modulator. The phase wavefronts were designed to accurately replicate the angular distribution of light intensity in the retina found in cataractous eyes with different severities. The induced amount of scatter ranged from values of straylight (S) from 10 to 85 degree2/sr, which corresponds from normal aging eye to advanced cataract stages. Mesopic visual acuity (VA) and contrast sensitivity (CS) at 3 cycles per degree were measured at the fovea and two retinal eccentricities (5 and 10 degrees in nasal visual field). We observed a consistent linear decline in VA (expressed in LogMAR) as the amount of induced scatter (quantified by the straylight parameter S) increased, both at the fovea and in the periphery. The effect of induced scattering on mesopic VA and CS at the fovea and the near periphery was evaluated. We found a relatively lower impact of scatter in the near periphery. This may explain the modest improvement in vision often found after cataract surgery in patients with AMD.

2.
Sci Rep ; 14(1): 8592, 2024 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615153

RESUMO

Multifocal contact lenses (MCLs) are one of the solutions to correct presbyopia, but their adoption is not widespread. To address this situation, visual simulators can be used to refine the adaptation process. This study aims to obtain accurate simulations for a visual simulator (SimVis Gekko; 2EyesVision) of daily soft MCL designs from four manufacturers. In-vitro characterization of these MCLs-several powers and additions- was obtained using NIMO TR-1504. From the averaged relative power profiles across powers, phase maps were reconstructed and the Through-Focus Visual Strehl metric was calculated for each MCL design. The SimVis Gekko simulation corresponding to each MCL design was obtained computationally and bench-validated. Finally, the MCL simulations were clinically validated involving presbyopic patients. The clinical validation results show a good agreement between the SimVis Gekko simulations and the real MCLs for through-focus visual acuity (TF-VA) curves and VA at three real distances. All MCL designs showed a partial correlation higher than 0.90 and a Root Mean Square Error below 0.07 logMAR between the TF-VA of simulations and Real MCLs across subjects. The validity of the simulation approach using SimVis Gekko and in-vitro measurements was confirmed in this study, opening the possibility to accelerate the adaptation of MCLs.


Assuntos
Lentes de Contato Hidrofílicas , Lagartos , Presbiopia , Humanos , Animais , Simulação por Computador , Presbiopia/terapia , Acuidade Visual
3.
J Clin Med ; 12(14)2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37510792

RESUMO

Evaluating chromatic aberration for a multifocal intraocular lens (MIOL) in vitro is essential for studying its performance because it helps determine the most appropriate lens for each patient, enhancing surgical outcomes. While refractive MIOLs with angular power variation have shown positive clinical outcomes, studies of these MIOLs on optical benches primarily employed monochromatic green light, neglecting the impact of longitudinal chromatic aberration (LCA) on MIOL performance. To address this gap, we evaluated the through-focus modulation transfer function (TF-MTF) and the point spread function (PSF) of two refractive segmented extended depth of focus intraocular lenses (IOLs) (Femtis Comfort and Precizon Presbyopic), comparing the results with those obtained with two widely known diffractive multifocal intraocular lenses (AcrySof IQ ReSTOR and FineVision Pod F). Measurements of the TF-MTF were conducted using both monochromatic and polychromatic light in a customized optical bench. The refractive designs exhibited distinct haloes in the PSFs. When comparing the refractive and diffractive designs, opposite signs of LCA were observed at near foci. These findings emphasize the influence of the optical design of IOLs on their performance under polychromatic light, providing valuable information for vision care professionals when selecting the most suitable lens for each patient.

4.
Biomed Opt Express ; 14(5): 2365-2374, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37206145

RESUMO

In this work, we propose a new diffractive trifocal intraocular lens design with focus extension, conceived to provide a high visual performance at intermediate distances. This design is based on a fractal structure known as the "Devil's staircase". To assess its optical performance, numerical simulations have been performed with a ray tracing program using the Liou-Brennan model eye under polychromatic illumination. The simulated through the focus visual acuity was the merit function employed to test its pupil-dependence and its behavior against decentering. A qualitative assessment of the multifocal intraocular lens (MIOL) was also performed experimentally with an adaptive optics visual simulator. The experimental results confirm our numerical predictions. We found that our MIOL design has a trifocal profile, which is very robust to decentration and has low degree of pupil dependence. It performs better at intermediate distances than at near distances and, for a pupil diameter of 3 mm, it works like an EDoF lens over almost the entire defocus range.

6.
J Clin Med ; 11(5)2022 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-35268303

RESUMO

Most of the new premium models of intraocular lenses for presbyopia correction use diffractive optics in their optical design. The presence of multiple foci and the difference of the diffractive efficiency for different wavelengths have a great impact in the lens optical performance. In this context, there is a limited information available for clinicians to understand the optical principles that differentiate each design and their potential influence on clinical outcomes. Optical bench studies with polychromatic light are necessary to solve this limitation. In this work, a custom made optical bench was employed to assess with polychromatic light the through the focus optical quality of three different IOL designs: trifocal, EDOF effect; and enhanced monofocal. By using different and complimentary approaches: images of the USAF test, axial PSFs and TF-MTFs, each design revealed its intrinsic features, which were not previously reported for these IOLs models in a comparative way. It was found that the chromatic aberration plays a very important role in the performance of each IOL. Our results could help clinicians to understand the optical principle of each lens and also provide useful information for choosing the lens that best suits the needs of the individual patient.

7.
J Clin Med ; 11(6)2022 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-35329805

RESUMO

This study aimed to evaluate in vitro performance refractive segmented EDOF intraocular lenses under polychromatic light using an optical bench that complies with the ISO 11979-2 Norm. The through focus modulation transfer function (TF-MTF) of the Femtis Comfort LS-313 MF15 (Oculentis GmbH, Berlin, Germany) IOL was evaluated for IOLs with three different base powers. The effect of the asymmetry of the segmented designs was evaluated with 3 different wavelengths and with polychromatic light at a 3.0 mm and 5.0 mm pupil diameter. It was demonstrated that the TF-MTF curves exhibit a bifocal profile that, in practice, results in an EDOF design. As a consequence of the LCA, the TF-MTF values in white light were lower than in monochromatic light. Images of the USAF test chart were obtained to confirm the prediction of the TF-MTFs. We found that Femtis Comfort is a bifocal low-addition IOL and this fact can result in an EDOF effect which was obtained previously in clinical trials. Moreover, we showed that the base power influences the IOL optical quality, which results as more effective for high powers (hyperopic eyes) than for low powers (myopic eyes). The LCA of the segmented refractive design was very low and presumably not clinically relevant.

8.
Sci Rep ; 11(1): 6620, 2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33758219

RESUMO

Corneal inlays (CIs) are the most recent surgical procedure for the treatment of presbyopia in patients who want complete independence from the use of glasses or contact lenses. Although refractive surgery in presbyopic patients is mostly performed in combination with cataract surgery, when the implantation of an intraocular lens is not necessary, the option of CIs has the advantage of being minimally invasive. Current designs of CIs are, either: small aperture devices, or refractive devices, however, both methods do not have good performance simultaneously at intermediate and near distances in eyes that are unable to accommodate. In the present study, we propose the first design of a trifocal CI, allowing good vision, at the same time, at far, intermediate and near vision in presbyopic eyes. We first demonstrate the good performance of the new inlay in comparison with a commercially available CI by using optical design software. We next confirm experimentally the image forming capabilities of our proposal employing an adaptive optics based optical simulator. This new design also has a number of parameters that can be varied to make personalized trifocal CI, opening up a new avenue for the treatment of presbyopia.


Assuntos
Córnea/cirurgia , Presbiopia/cirurgia , Procedimentos Cirúrgicos Refrativos/métodos , Humanos , Presbiopia/diagnóstico , Resultado do Tratamento , Testes Visuais , Acuidade Visual
9.
Appl Opt ; 59(13): D54-D58, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400623

RESUMO

A new class of diffraction-based corneal inlays for treatment of presbyopia is described. The inlay is intended to achieve an improvement of the near focus quality over previous designs. Our proposal is a two-zone hybrid device with separated amplitude and phase areas having a central aperture and no refractive power. An array of micro-holes is distributed on the surface of the inlay conforming a binary photon sieve. In this way, the central hole of the disk contributes to the zero order of diffraction, and the light diffracted by the micro-holes in the peripheral photon sieve produces a real focus for near vision. We employed ray-tracing software to study the performance of the new inlay in the Liou-Brennan model eye. The modulation transfer functions (MTFs) at the distance and near foci, and the area under the MTFs for different object vergences, were the merit functions used in the evaluation. The results were compared with those obtained with previous pure amplitude designs. Additionally, image simulations were performed with the inlays in the model eye to show the good performance of our proposal in improving the quality of the near vision.


Assuntos
Córnea/metabolismo , Transplante de Córnea/métodos , Miopia/metabolismo , Presbiopia/metabolismo , Simulação por Computador , Topografia da Córnea , Humanos , Modelos Biológicos , Modelos Teóricos , Implantes Orbitários , Refração Ocular , Visão Binocular , Acuidade Visual
10.
J Ophthalmol ; 2019: 9382467, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31827914

RESUMO

PURPOSE: To assess the imaging properties of two different designs of a new concept of corneal inlays whose working principle is based on diffraction. METHODS: The quality of the retinal images provided by Diffractive Corneal Inlays (DCIs) was evaluated theoretically in comparison with Small Aperture Corneal Inlay (SACI). ZEMAX OpticStudio software was employed for the simulations in an eye model with different pupil diameters (3.0 mm and 4.5 mm). The employed merit functions in the analysis were the Modulation Transfer Function (MTF), the area under the MTF (MTFa), and the Point Spread Function (PSF). Comparison was made with the SACI at different defocus conditions. RESULTS: The bifocal nature of the DCIs was demonstrated in a model eye for the first time. It was shown that the intensity of the near focus depends on the radius of the central zone. Retinal image quality of the DCI was equal to or exceeded the SACI in the majority of visual conditions as was demonstrated with simulated images. CONCLUSIONS: A new customizable type of corneal inlays has been evaluated using objective numerical simulations. Improvements in imaging of near objects and in light throughput compared with the popular small aperture inlays were demonstrated. These findings open a new technical branch of minimally invasive surgical solutions for the treatment of presbyopia.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...